3065   Record sequence exception in transaction journal

Cause

This error occurs if a record in the transaction journal is out of sequence or corrupted. The header of each journal record contains an integral sequence number and a timestamp.

The sequence number in each journal record must be exactly one higher than the number in its predecessor, and the timestamp must be valid and greater than or equal to its predecessor.

Action

If this error results in a failure in database recovery, the database must be restored from backup.

If the problem occurred during a system crash recovery, it may still be possible to perform an archival recovery by using the last backup and recovering through the transaction journals up to the point where the journals become invalid.