Product Information > JADE Error Messages and System Messages > 14000 through 14999 - JADE User Interface Errors > 14119 - A Thin Client reconnection attempt ended up on the wrong application server

14119   A Thin Client reconnection attempt ended up on the wrong application server

Cause

This error occurs when a presentation client connection is lost and an attempted reconnection to the original application server reached a different application server instead. (The applications check that the presentation client has connected to the correct application server.)

Action

If the application server with active users is closed and then quickly restarted, this error is normal (that is, the reconnection found the new application server).

If the application server has not been closed and this error occurs, the network configuration is not set up correctly for JADE operation. When the first connection succeeds, the application server’s IP address is queried. This IP address is subsequently used to ensure the correct application server is reached if the connection is lost and an attempted reconnection is initiated. If the use of this IP address did not achieve the expected result and another application server was reached instead, the network configuration should be adjusted accordingly