Product Information > JADE Error Messages and System Messages > 14000 through 14999 - JADE User Interface Errors > 14118 - Second application started by a thin client ended up on the wrong application server

14118   The start of a second application by a thin client did not end up on the correct application server

Cause

This error occurs when a presentation client has initiated a second application and the TCP connection was made to an application server that differs from the one running the first application. (The applications check that the presentation client has connected to the correct application server.)

Action

The network configuration is not set up correctly for JADE operation. When the first connection succeeds, the application server’s IP address is queried. This IP address is subsequently used to ensure the correct application server is reached if another application is initiated. If the use of this IP address did not achieve the expected result and another application server was reached instead, the network configuration should be adjusted accordingly.